FM-3 Programming Module Reference Manual

Line Voltage (EN ONLY)

LineVoltage

This parameter is used to calculate critical internal gains. There are two possible value: 115 or 230 VAC. A value of 115 VAC should not be used if the actual line voltage is 230, otherwise damage to the EN drive may result. The default value is 230 VAC.

BaudRate

Modbus.BaudRate

Modbus baudrate for this FM module and drive.

Modbus Id

Modbus.ModbusId

Modbus ID # for this FM module and drive.

Debounced

ModuleInput.#.Debounced

This is the state of the input after the debounce is taken into account.

Module Input Debounce Time

ModuleInput.#.DebounceTime

The Module Input Debounce Time parameter is the minimum time a digital input must be on in order to be recognized by the FM-3. This feature helps prevent false triggering in applications in electrically noisy environments.

Module Input Force

ModuleInput.#.Force

Input can be forced either On or Off. This bit is the state to which the input will be forced when the ForceEnable bit is activated.

Module Input Enable Force

ModuleInput.#.ForceEnable

If ModuleInput.#.ForceEnable is True (or On), then the state of the ModuleInput.#.Force bit will override the current input state.