Programming

Endif

 

Loop

 

Jog.Stop

‘Stop jogging when the Jog+ input goes off.

Endif

 

Loop

 

Playback Program (Program 2)

 

Home.0.Initiate

‘Sensor,Offset=0.000in,Vel=-10in/s

Do While (TRUE)

‘Repeat until the program is halted

Index.1.Initiate

‘Absolute,Posn=1.000in,Vel=5in/s

Wait For InPosn

 

ModuleOutput.1=ON

‘Turn on ModuleOutput.1 for 1 second

Wait For Time 1.000

‘seconds

ModuleOutput.1=OFF

 

Index.2.Initiate

‘Absolute,Posn=20.000in,Vel=7in/s

Wait For InPosn

 

ModuleOutput.1=ON

‘Turn on ModuleOutput.1 for 1 second

Wait For Time 1.000

‘seconds

ModuleOutput.1=OFF

 

Index.3.Initiate

‘Absolute,Posn=5.250in,Vel=10in/s

Wait For InPosn

 

ModuleOutput.1=ON

‘Turn on ModuleOutput.1 for 1 second

Wait For Time 1.000

‘seconds

ModuleOutput.1=OFF

 

Loop

 