Parameter Descriptions
Start Up
StartUp
This source can be used to trigger an event to occur on startup (when the
Stop
Stop
Activate this destination to stop all motion and programs. If Stop is activated when a Jog, Index, Home or Program is in progress, they will decelerate to zero speed at the Stop Decel ramp. When Stop is active, all Jog, Home, Index and Program initiate destinations will be ignored. When it is deactivated, all level sensitive and active input functions (Jog.0.PlusActivate, Jog.0.MinusActivate, etc.) will become operational. For example, if the Jog.PlusActivate input function is active when the Stop input function is deactivated, the Jog.Plus motion will initiate using the acceleration found in the Jog.0.Accel parameter. This is level sensitive.
Stop Deceleration
StopDecel
Deceleration rate used when the Stop destination is activated.
Torque Command
TorqueCommand
This parameter is the torque command value before it is limited. The torque command may be limited by either the Torque Limit (if the Torque Limit Enable destination is active) or current foldback.
Limited Torque Command
TorqueCommandLimited
This is the actual torque commanded to the motor. This value is the result after the TorqueCommand is limited by the current foldback or the TorqueLimit value (if enabled).