Setting Up Parameters

Figure 46: Tying a Source to a Destination

Assignment Polarity

The active state of an assignment can be programmed to be Active Off, Active On, or Custom using PowerTools Pro. Making an assignment “Active On” means that the destination will be active when the source it is assigned to becomes active, and is inactive when the source is inactive. Making an assignment “Active Off” means that the destination will be active when the source it is assigned to is inactive, and will be inactive when the source is active.

The polarity of the assignment can also be changed to Custom when required. Custom polarity allows you to make a destination activate and deactivate based on two different sources.

75

Page 89
Image 89
Emerson FM-3 manual Assignment Polarity, Tying a Source to a Destination