Setting Up Parameters
Foldback RMS
This parameter accurately models the thermal heating and cooling of the drive and motor. When it reaches 100 percent, current foldback will be activated. See the Diagnostics section for an explanation of foldback.
Shunt Power RMS
This parameter models the thermal heating and cooling of the drive internal shunt. This parameter indicates the percent of shunt capacity utilization. When this value reaches 100 percent, the drive will generate an RMS Shunt Power Fault. This parameter is not applicable to the
Information Tab (Online Only)
Drive Information Group
Firmware Part Number
Displays the part number of the drive firmware you are using.
Firmware Revision
Displays the revision of the drive firmware you are using.
Serial Number
Displays the serial number of the drive with which you are currently online.
Module Information Group
Firmware Part Number
Displays the part number of the
Firmware Revision
Displays the revision of the firmware in the
Serial Number
Displays the serial number of the
37