Fujitsu SRS-1050 manual Connecting To The, Network, Entering Spids And A D, Channel Tei

Models: SRS-1050

1 131
Download 131 pages 52.77 Kb
Page 95
Image 95
CONNECTING TO THE

SRS -1050 Installation (

Appendix B

 

 

 

 

 

CONNECTING TO THE

 

If you have only one SPID for

 

NETWORK

 

both voice and data, enter the

 

 

 

SPID as a voice SPID only. Do

 

When you receive your SRS-1050,

 

not enter the same SPID twice (for

 

plug the telephone line from the

 

voice and data).

 

wall into the LINE socket on the

 

 

 

back of the set. If the display

 

Do not change your SPID unless

 

shows a date and time, you have

 

told to do so by your service

 

power. If the display does not

 

provider. In most cases, digital

 

light up, you may need a power

 

sets will not work without the

 

supply to connect to the wall

 

correct SPID number. If the SPID

 

socket and to the 40 V DC power

 

number is wrong, the set displays

 

socket on the back of the set.

 

the message SPID NG. Enter the

 

 

 

correct SPID number, and then

 

If you are connecting power for

 

disconnect and reconnect power

 

the first time, you should see the

 

to make the set function normally.

 

message SPID NG. See the next

 

 

 

section to enter a Service Profile

 

To enter the service profile

 

Identifier (SPID).

 

identifiers and the terminal

 

 

 

endpoint identifier, follow these

 

 

 

steps:

 

ENTERING SPIDS AND A D-

 

 

 

CHANNEL TEI

 

1. Press REGISTER (softkey 4) 8,

 

 

 

ENTER (softkey 1).

 

The Service Profile Identifier

 

 

 

identifies your set to the network.

 

The message ENTER VOICE SPID

 

If you have a voice/data terminal,

 

appears, with the current SPID

 

you may need two SPIDs, one for

 

number (if any) shown below it.

 

voice and one for B-channel

 

 

 

ENTER VOICE SPID

 

circuit-switched data. You may

 

 

also need to enter a D-channel

 

ID=000000000000

 

Terminal Endpoint Identifier (TEI)

 

2. Dial your voice SPID number

 

for packet-switched data calls.

 

 

 

and press ENTER.

 

You can enter the data SPID and

 

 

 

 

 

TEI either through this procedure

 

The display prompts for the data

 

or through procedures in the

 

 

 

SPID, if you have a data model.

 

Data User's Guide.

 

 

 

 

 

 

 

 

 

 

 

ENTER DATA SPID

 

 

 

ID=

 

 

 

 

 

Page B-4

Page 95
Image 95
Fujitsu SRS-1050 manual Connecting To The, Network, Entering Spids And A D, Channel Tei, Data Users Guide