Appendix B

( SRS -1050 Installation

Multiple Unit Installations

Bridging at the NT1

The overall maximum length of cable is 1600 ft. The TR switch on the Terminal Equipment farthest from the NT1 should be ON. The TR switches on all other Terminal Equipment should be OFF. The TR switches on the NT1 should be set to ON at 100 Ohms. NT1 timing switches (if present) should be set to ADAPTIVE (or PTP).

NT1 (TR = ON 100 Ohms)

Terminal Equipment (TR = OF

Terminal Equipment (TR = OF Terminal Equipment (TR = ON

System Administrator’s Reference

Feature Activator and Button Placement

 

Subscribed Feature

Assigned FA/FI

SRS-1050 Button

 

3 way conference

FA 18/FI 18

18

 

 

 

FA 60/FI 60

18

 

 

Drop

FA 19/FI 19

19

 

 

 

FA 62/FI 62

19

 

 

Transfer

FA 20/FI 20

20

 

 

 

FA 61/FI 61

20

 

 

Message Waiting

FA 63/FI 63

Message waiting LED

 

Bridge Call Exclusion

FA XX/FI XX

XX

 

 

FA 59/FI 59

17

 

 

Privacy (Bridged Call

FA XX/FI XX

XX

 

Exclusion)

FA 58/FI 58

16

 

 

Call Forwarding

FA XX/FI XX

XX

 

Variable

FA 57/FI 57

15

 

 

 

 

 

 

Page B-23

Page 114
Image 114
Fujitsu SRS-1050 manual Multiple Unit Installations, Fa Xx/Fi