Fujitsu SRS-1050 Program and Loop Switch Test, Exiting Test Mode, Table C-1, Display Message

Models: SRS-1050

1 131
Download 131 pages 52.77 Kb
Page 119
Image 119
Program and Loop Switch Test

S RS -1050 Testing (

Appendix C

SELF TEST (MEMORY/LINE)

VOICE & DATA ALL GOOD

Program and Loop Switch Test

If your SRS-1050 has the optional data terminal adapter, pressing 5 displays the status of the Program (PRG) and Loop switches that are a part of the TA. The display looks like this:

SELF TEST (PROGRAM SW/LOOP SW)

PROG RAM: OFF LOOP:NOR

Pressing the Program switch on the back of the set changes PROG RAM: OFF to PROG RAM: ON. Pressing the Loop switch changes LOOP: NOR to LOOP: TEST. See your Data User's Guide for the function of these switches.

Exiting Test Mode

To exit test mode, remove power and reapply it.

Table C-1

Self-Test Result Codes

 

 

Display Message

Test Result

 

 

S/M ERROR CODE (01)

SMCM, RAM, ROM test failed.

S/M ERROR CODE (02)

Line SIU test failed.

S/M ERROR CODE (03)

Line SIU test timed out.

S/M ERROR CODE (04)

Line NT test failed; message received

............................................................

does not match message sent.

S/M ERROR CODE (05)

Line NT test timed out.

S/M ERROR CODE (06)

Line NT test failed; no response

............................................................

received.

S/M ERROR CODE (07)

SMCM test timed out.

S/M ERROR CODE (07)

SMCM, RCM test timed out.

RCM (02)

 

RCM ERROR CODE (01)

RCM RAM test failed.

RCM ERROR CODE (02)

RCM test timed out.

VOICE ALL GOOD

All tests passed.

VOICE & DATA ALL GOOD

All tests passed (with data terminal

Page C-4

Page 119
Image 119
Fujitsu SRS-1050 manual Program and Loop Switch Test, Exiting Test Mode, Table C-1, Self-Test Result Codes, Display Message