Diagnostics

1

Was an event code 300, 301, 302, 303, 304, 305, 306, 307; or 604, 605, 607; or 800, 801, 802, 805, 806, 807, 810, 811, 812, or 850 observed at the switch Event Log (HAFM server) or at the embedded web server event log?

YES NO

Go to step 3.

2

The following table lists event codes, brief explanations of the codes, and associated steps that describe fault isolation procedures.

Event

 

 

Code

Explanation

Action

 

 

 

300

First cooling fan failed.

Go to step 8.

 

 

 

301

Second cooling fan failed.

Go to step 8.

 

 

 

302

Third cooling fan failed.

Go to step 8.

 

 

 

303

Fourth cooling fan failed.

Go to step 8.

 

 

 

304

Fifth cooling fan failed (does not apply

Go to step 8.

 

to edge switch 2/16).

 

 

 

 

305

Sixth cooling fan failed (does not apply

Go to step 8.

 

to edge switch 2/16).

 

 

 

 

604

SBAR failure.

Go to step 14.

 

 

 

605

SBAR revision not supported.

Go to step 12.

 

 

 

607

Switch contains no operational SBAR

Go to step 14.

 

assemblies.

 

 

 

 

800

High-temperature warning (port

Go to step 8.

 

module sensor)

 

 

 

 

801

Critically hot temperature warning (port

Go to step 8.

 

module thermal sensor)

 

 

 

 

802

Port module shutdown due to thermal

Go to step 8.

 

violations.

 

 

 

 

805

High-temperature warning (SBAR

Go to step 8.

 

module thermal sensor).

 

 

 

 

806

Critically hot temperature warning

Go to step 8.

 

(SBAR assembly thermal sensor).