Diagnostics
1
Was an event code 300, 301, 302, 303, 304, 305, 306, 307; or 604, 605, 607; or 800, 801, 802, 805, 806, 807, 810, 811, 812, or 850 observed at the switch Event Log (HAFM server) or at the embedded web server event log?
YES NO
↓Go to step 3.
2
The following table lists event codes, brief explanations of the codes, and associated steps that describe fault isolation procedures.
Event |
|
|
Code | Explanation | Action |
|
|
|
300 | First cooling fan failed. | Go to step 8. |
|
|
|
301 | Second cooling fan failed. | Go to step 8. |
|
|
|
302 | Third cooling fan failed. | Go to step 8. |
|
|
|
303 | Fourth cooling fan failed. | Go to step 8. |
|
|
|
304 | Fifth cooling fan failed (does not apply | Go to step 8. |
| to edge switch 2/16). |
|
|
|
|
305 | Sixth cooling fan failed (does not apply | Go to step 8. |
| to edge switch 2/16). |
|
|
|
|
604 | SBAR failure. | Go to step 14. |
|
|
|
605 | SBAR revision not supported. | Go to step 12. |
|
|
|
607 | Switch contains no operational SBAR | Go to step 14. |
| assemblies. |
|
|
|
|
800 | Go to step 8. | |
| module sensor) |
|
|
|
|
801 | Critically hot temperature warning (port | Go to step 8. |
| module thermal sensor) |
|
|
|
|
802 | Port module shutdown due to thermal | Go to step 8. |
| violations. |
|
|
|
|
805 | Go to step 8. | |
| module thermal sensor). |
|
|
|
|
806 | Critically hot temperature warning | Go to step 8. |
| (SBAR assembly thermal sensor). |
|
|
|
|