Diagnostics
13
The port SFP may be improperly seated in the chassis. Partially remove and reseat the SFP, then perform an external loopback test for the SFP.
Did reseating the port SFP solve the problem?
NO YES
↓The switch appears operational.
Go to step 11.
14
The fabric is initializing or a problem with the
•Offline - the port is blocked and transmitting the offline sequence (OLS) to the attached switch, or the port is unblocked and receiving the OLS, indicating the attached switch is set offline.
•Not Operational - the port is receiving the Fibre Channel not operational sequence (NOS), indicating the attached switch failed.
•No light (any port) - no signal (light) is received by the port. This is a normal condition when there is no cable attached to the port SFP or when the attached switch or fabric device is powered off.
Inform the customer an attached switch or fabric device is powered off, set offline, or failed.
15
Beaconing is enabled for the port.
a.Consult with the customer and next level of support to determine the reason port beaconing is enabled.
b.Disable port beaconing:
1.At the Hardware View,
2.Click Enable Beaconing. The check mark disappears from the box adjacent to the option, and port beaconing is disabled.
Was port beaconing enabled because port failure or degradation was suspected?
YES NO