Event Codes
Event Code: 070 (continued)
Distributio | Switch |
| HAFM Server |
| Host |
| ||
n: |
|
|
|
|
|
|
| |
EWS | System | Event | Sense | Link | ||||
| ||||||||
| Event | Error | Log |
| e | Info | Incident | |
| Log | LED |
|
|
|
|
| |
|
|
|
|
|
|
|
| |
| 4 |
| 4 |
|
|
|
| |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| ||
|
|
| Event Code: 071 |
|
|
| ||
|
|
|
|
|
|
| ||
Message: | Switch is isolated. |
|
|
|
|
| ||
|
|
|
|
|
|
| ||
Severity: | Informational. |
|
|
|
|
|
Explanatio The switch is isolated from other fabric elements (directors or switches). This event code
n:is accompanied by one or more 070 event codes. Refer to the event data for the segmentation reason.
Action: | Action depends on the segmentation reason specified in the event data. |
|
|
Event | The first byte of event data (byte 0) specifies the E_Port number. The fifth byte (byte 4) |
Data: | specifies the segmentation reason as follows: |
| 1 = Incompatible operating parameters. Ether the resource allocation time out value |
| (R_A_TOV) or error detect time out value (E_D_TOV) is inconsistent between the |
| switch and another fabric element (director or switch). Modify the R_A_TOV and |
| E_D_TOV to make the values consistent for all fabric directors and switches. |
| 2 = Duplicate domain ID. The switch has the same preferred domain ID as another |
| fabric element (director or switch). Modify the switch’s Domain ID to make it unique. |
| 3 = Incompatible zoning configurations. The same name is applied to a zone for the |
| switch and another fabric element (director or switch), but the zones contain different |
| zone members. Modify the zone name to make it unique, or ensure zones with the same |
| name contain identical zone members. |