Diagnostics

3

The following table lists event codes, brief explanations of the codes, and associated steps that describe fault isolation procedures.

Event

 

 

Code

Explanation

Action

 

 

 

080

Unauthorized world wide name

Go to step 21

 

 

 

440

Embedded port hardware failure.

Go to step 11.

 

 

 

504

Port module failure - error threshold

Go to step 11.

 

exceeded.

 

 

 

 

506

Fibre Channel port failure.

Go to step 11.

 

 

 

507

Loopback diagnostics port failure.

Go to step 12.

 

 

 

508

Fibre Channel port anomaly detected.

Go to step 12.

 

 

 

512

SFP nonfatal error.

Go to step 11.

 

 

 

514

SFP failure.

Go to step 11.

 

 

 

581

Implicit incident.

Go to step 32.

 

 

 

582

Bit-error threshold exceeded.

Go to step 34.

 

 

 

583

Loss of signal or loss of synchronization.

Go to step 32.

 

 

 

584

Not operational primitive sequence

Go to step 32.

 

(NOS) received.

 

 

 

 

585

Primitive sequence timeout

Go to step 33.

 

 

 

586

Invalid primitive sequence received for

Go to step 33.

 

link state.

 

 

 

 

604

SBAR module failure.

Go to step 32.

 

 

 

4

Is fault isolation being performed at the switch or HAFM server?

YES NO

Fault isolation is being performed through the embedded web server interface. Go to step 35.

5

Is the amber LED adjacent to a Fibre Channel port illuminated, but not blinking?