| Event Codes | |
|
|
|
|
|
|
|
| |
|
|
| Event Code: 202 |
|
|
| ||
|
|
|
|
|
|
|
| |
Message: | Power supply thermal failure. |
|
|
|
| |||
|
|
|
|
|
|
|
| |
Severity: | Major. |
|
|
|
|
|
| |
|
| |||||||
Explanatio | The thermal sensor associated with a power supply indicates an overheat condition that | |||||||
n: | shut down the power supply. The second power supply assumes the full operating load | |||||||
| for the switch. |
|
|
|
|
| ||
|
| |||||||
Action: | Replace the failed power supply. Perform the data collection procedure and return the | |||||||
| Zip disk and failed power supply to Hewlett Packard support personnel. |
| ||||||
|
|
|
|
| ||||
Event | No supplementary data included with this event. |
|
|
| ||||
Data: |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| |
Distributio | Switch |
| HAFM Server |
| Host |
| ||
n: |
|
|
|
|
|
|
| |
EWS | System | Event | Sense | Link | ||||
| ||||||||
| Event | Error | Log |
| e | Info | Incident | |
| Log | LED |
|
|
|
|
| |
|
|
|
|
|
|
|
| |
| 4 | 4 | 4 | 4 | 4 | 4 |
| |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| ||
|
|
| Event Code: 203 |
|
|
| ||
|
|
|
|
|
| |||
Message: | Power supply AC voltage recovery. |
|
|
|
| |||
|
|
|
|
|
|
| ||
Severity: | Informational. |
|
|
|
|
| ||
|
| |||||||
Explanatio | AC voltage recovered for the power supply. Both power supplies adjust to share | |||||||
n: | operating load for the switch. |
|
|
|
| |||
|
|
|
|
|
|
| ||
Action: | No action required. |
|
|
|
|
| ||
|
|
|
|
| ||||
Event | No supplementary data included with the event. |
|
|
| ||||
Data: |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| ||
Distributio | Switch |
| HAFM Server |
| Host |
| ||
n: |
|
|
|
|
|
|
| |
EWS | System | Event | Sense | Link | ||||
| ||||||||
| Event | Error | Log |
| e | Info | Incident | |
| Log | LED |
|
|
|
|
| |
|
|
|
|
|
|
|
| |
| 4 |
| 4 |
|
|
|
| |
|
|
|
|
|
|
|
|