Diagnostics
Event |
|
|
Code | Explanation | Action |
|
|
|
807 | SBAR assembly shutdown due to | Go to step 8. |
| thermal violation. |
|
|
|
|
810 | High temperature warning (CTP card | Go to step 8. |
| thermal sensor). |
|
|
|
|
811 | Critically hot temperature warning | Go to step 8. |
| (CTP card thermal sensor). |
|
|
|
|
812 | CTP card shutdown due to thermal | Go to step 8. |
| violation. |
|
|
|
|
850 | System shutdown due to CTP card | Go to step 8. |
| thermal violations. |
|
|
|
|
3
Is remote fault isolation being performed at the switch or HAFM server?
YES NO
↓Remote fault isolation is being performed through the embedded web server interface. Go to step 6.
4
Does a blinking red and yellow diamond (failed FRU indicator) appear to overlay a fan (cooling fan assembly) graphic at the Hardware View?
NO YES
↓Go to step 8.
5
Does inspection of a fan indicate a failure? Indicators include:
•The amber LED at the upper left corner of a fan illuminates.
•The fan is not rotating.
NO YES
↓Go to step 8.
The switch appears operational.