Diagnostics

Event

 

 

Code

Explanation

Action

 

 

 

807

SBAR assembly shutdown due to

Go to step 8.

 

thermal violation.

 

 

 

 

810

High temperature warning (CTP card

Go to step 8.

 

thermal sensor).

 

 

 

 

811

Critically hot temperature warning

Go to step 8.

 

(CTP card thermal sensor).

 

 

 

 

812

CTP card shutdown due to thermal

Go to step 8.

 

violation.

 

 

 

 

850

System shutdown due to CTP card

Go to step 8.

 

thermal violations.

 

 

 

 

3

Is remote fault isolation being performed at the switch or HAFM server?

YES NO

Remote fault isolation is being performed through the embedded web server interface. Go to step 6.

4

Does a blinking red and yellow diamond (failed FRU indicator) appear to overlay a fan (cooling fan assembly) graphic at the Hardware View?

NO YES

Go to step 8.

5

Does inspection of a fan indicate a failure? Indicators include:

The amber LED at the upper left corner of a fan illuminates.

The fan is not rotating.

NO YES

Go to step 8.

The switch appears operational.