Repair Information

03 ELP rejected by the attached switch. This director/switch transmitted an exchange link protocol (ELP) frame that was rejected by the switch at the other end of the ISL.

04 Incompatible switch at the other end of the ISL. Interop mode for this switch is set to Open Fabric mode and the switch at the other end of the ISL is a Hewlett Packard switch configured for Homogeneous Fabric mode.

05 External loopback adapter connected to the port. A loopback plug. is connected to the port and there is no diagnostic test running.

06 N_Port connection not allowed on this port. The port type configuration does not match the actual port use. Port is configured as an E_Port, but attaches to a node device.

07 Non-Hewlett Packard switch at other end of the ISL. The cable is connected to a non-Hewlett Packard switch and interop mode is set to Homogeneous fabric mode.

08 ISL connection not allowed on this port. The port type configuration does not match the actual port use (the port is configured as an F_Port, but attaches to a switch or director).

10 Port binding violation - unauthorized WWN. The WWN entered to configure port binding is not valid or a nickname was used that is not configured through the product manager for the attached device.

11 Unresponsive node connected to port. Possible causes are:

Hardware problem on switch or on a connected node where ELP frames are not delivered, the response is not received, or a fabric login in (FLOGI) cannot be received. There may be problems in switch SBAR.

Faulty or dirty cable connection.

Faulty host bus adapters that do not send out FLOGI within reasonable time frame.

Threshold Alert - If a threshold alert exists for the port, an alert indicator (yellow triangle) will appear by the Threshold Alert field, and the configured name for the last alert received will appear in the field.