Diagnostics

The switch appears operational.

Go to step 4.

16

The port has an invalid attachment. The information in the Port Properties dialog box specifies the reason as listed in the following table.

Reason

Action

 

 

Unknown

Contact the next

 

level of support.

 

 

ISL connection not allowed on

Go to step 17.

this port.

 

 

 

Incompatible switch at other end

Go to step 18.

of ISL.

 

 

 

External loopback adapter

Go to step 19.

connected to the port.

 

 

 

N-Port connection not allowed

Go to step 17.

on this port.

 

 

 

Non-Hewlett Packard switch at

Go to step 18.

other end of the ISL.

 

 

 

Port binding violation -

Go to step 21.

Unauthorized WWN.

 

 

 

Unresponsive node connected

Go to step 22.

to port.

 

 

 

17

The port connection conflicts with the configured port type. Either an expansion port (E_Port) is incorrectly cabled to a Fibre Channel device or a fabric port (F_Port) is incorrectly cabled to a fabric element (director or switch).

a.At the HAFM server’s Hardware View, click the Configure icon at the navigation control panel and select Ports from the Configure menu. The Configure Ports dialog box (open systems mode) displays.