Diagnostics
Did service of the HBAs solve the problem?
NO YES
↓Exit MAP.
Contact the next level of support. Exit MAP.
24
The switch and attached fabric device are performing a Fibre Channel link reset. This is a transient state. Wait approximately 30 seconds and inspect port state and LED behavior.
Did the link recover and resume operation?
NO YES
↓The Fibre Channel link and switch appear operational.
Go to step 4.
25
A link incident message appeared in the Link Incident Log or in the Link Incident field the Port Properties dialog box.
Clear the link incident for the port.
a.At the Hardware View,
b.Select Clear Link Incident Alert(s). The Clear Link Incident Alert(s) dialog box displays.
c.Select the This port (n) only radio button (where n is the port number) and click OK. The link incident clears.
d.Monitor port operation for approximately five minutes.
Did the link incident recur?
YES NO