Diagnostics
↓Go to step 14.
11
Click the icon representing the switch reporting the problem. The Hardware View displays. At the Hardware View:
•Observe whether the edge switch 2/16 Status table is yellow and switch status is
NOT OPERATIONAL.
•Inspect FRUs for a blinking red and yellow diamond (failed FRU indicator) that overlays a FRU graphic.
Does a blinking red and yellow diamond overlay a Fibre Channel port graphic?
NO YES
↓A port SFP failure is indicated. Go to step 23 to obtain event codes. If no event codes are found, go to "MAP 0600: Port Failure and Link Incident Analysis" on page
12
Does a blinking red and yellow diamond overlay a fan graphic?
NO YES
↓A fan failure is indicated. Go to step 23 to obtain event codes. If no event codes are found, go to "MAP 0500: Fan and CTP Failure Analysis" on page
13
A blinking red and yellow diamond overlays a power supply graphic.
A power supply failure is indicated. Go to step 23 to obtain event codes. If no event codes are found, go to "MAP 0100: Power Distribution Analysis" on page
14
Does a yellow triangle (attention indicator) appear at the alert panel and as the background to the icon representing the switch reporting the problem?
YES NO
↓Go to step 18.
15
Click the icon representing the switch reporting the problem. The Hardware View displays. At the Hardware View: