Diagnostics

Go to step 14.

11

Click the icon representing the switch reporting the problem. The Hardware View displays. At the Hardware View:

Observe whether the edge switch 2/16 Status table is yellow and switch status is

NOT OPERATIONAL.

Inspect FRUs for a blinking red and yellow diamond (failed FRU indicator) that overlays a FRU graphic.

Does a blinking red and yellow diamond overlay a Fibre Channel port graphic?

NO YES

A port SFP failure is indicated. Go to step 23 to obtain event codes. If no event codes are found, go to "MAP 0600: Port Failure and Link Incident Analysis" on page 2-63.

12

Does a blinking red and yellow diamond overlay a fan graphic?

NO YES

A fan failure is indicated. Go to step 23 to obtain event codes. If no event codes are found, go to "MAP 0500: Fan and CTP Failure Analysis" on page 2-58.

13

A blinking red and yellow diamond overlays a power supply graphic.

A power supply failure is indicated. Go to step 23 to obtain event codes. If no event codes are found, go to "MAP 0100: Power Distribution Analysis" on page 2-26.

14

Does a yellow triangle (attention indicator) appear at the alert panel and as the background to the icon representing the switch reporting the problem?

YES NO

Go to step 18.

15

Click the icon representing the switch reporting the problem. The Hardware View displays. At the Hardware View: