FRU Removal and Replacement

d.Verify that the amber LED adjacent to the port is extinguished.

6.At the HAFM server’s Hardware View, select the Event Log option from the Logs icon. The Event Log displays. Ensure the following event code appears in the log:

513 - SFP hot-removal completed.

If an event code 513 does not appear in the log, go to "MAP 0000: Start MAP" on page 2-7to isolate the problem.

7.At the HAFM server’s Hardware View:

a.Ensure no alert symbols appear that indicate a failure (yellow triangle or red diamond).

b.Click the port graphic representing the replacement SFP to open the Port Properties dialog box. Verify that port information (port number, port name, operational state, and port technology) is correct.

If a problem is indicated, go to "MAP 0000: Start MAP" on page 2-7to isolate the problem.

8.Restore communication to the port and set the port online as directed by the customer (refer to "Unblock a Port" on page 3-39).

9.Perform the data collection procedure (refer to "Collecting Maintenance Data" on page 3-31).

10.Clear the switch’s system error (ERR) LED:

a.At the HAFM server’s Hardware View, right-click the front panel bezel graphic (away from a FRU) to open a pop-up menu.

b.Click the Clear System Error Light menu selection.

RRP: Power Supply

Use the following procedures to remove or replace a power supply from the rear of the switch. No tools are required.

Removal

To remove a power supply:

1.Identify the defective power supply from the extinguished green LED at the switch or failure information at the HAFM server’s Hardware View.