Diagnostics

22

Inspect the power supply operational states at the embedded web server interface.

a.At the View panel, click the Component Properties tab. The View panel (Component Properties tab) displays.

b.Inspect the State fields for Power Supply 0 and Power Supply 1.

Does the State field display a Failed or Not Installed message for either power supply?

NO YES

A redundant power supply failure is indicated. Go to step 6. The switch appears operational.

MAP 0200: POST, Reset, or IPL Failure Analysis

When the switch is powered on, it performs a series of power-on self-tests (POSTs). When POSTs complete, the switch performs an initial program load (IPL) that loads firmware and brings the unit online. This MAP describes fault isolation for problems that may occur during the POST/IPL process.

If an error is detected, the POST/IPL process continues in an attempt to initialize the switch and bring it online. But an event code 400 displays when the switch completes the POST/IPL process.

1

Was an event code 400 or 411 observed at the switch Event Log (HAFM server) or at the embedded web server event log?

YES NO

Analysis for the failure is not described in this MAP. Go to "MAP 0000: Start MAP" on page 2-7.