Event Codes
|
|
| Event Code: 302 |
|
|
| ||
|
|
|
|
|
|
|
| |
Message: | Cooling fan propeller failed. |
|
|
|
| |||
|
|
|
|
|
|
|
| |
Severity: | Major. |
|
|
|
|
|
| |
|
| |||||||
Explanatio | Three cooling fans (out of six) failed or are rotating at insufficient angular velocity. The | |||||||
n: | remaining fan is operational. The amber LED illuminates at the rear of the failed fans. | |||||||
|
|
|
|
|
| |||
Action: | Replace the indicated fan modules. |
|
|
|
| |||
|
|
| ||||||
Event | The first byte of event data (byte 0) specifies the failed fan numbers. |
| ||||||
Data: |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| |
Distributio | Switch |
| HAFM Server |
| Host |
| ||
n: |
|
|
|
|
|
|
| |
EWS | System | Event | Sense | Link | ||||
| ||||||||
| Event | Error | Log |
| e | Info | Incident | |
| Log | LED |
|
|
|
|
| |
|
|
|
|
|
|
|
| |
| 4 | 4 | 4 | 4 | 4 | 4 |
| |
|
|
|
|
|
|
|
|
Event Code: 303
Message: Cooling fan propeller failed.
Severity: Major.
Explanatio Four cooling fans (out of six) failed or are rotating at insufficient angular velocity. The
n:remaining fan is operational. The amber LED illuminates at the rear of the failed fans.
Action: | Replace the indicated fan modules. |
|
|
|
| |||
|
|
| ||||||
Event | The first byte of event data (byte 0) specifies the failed fan numbers. |
| ||||||
Data: |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| |
Distributio | Switch |
| HAFM Server |
| Host |
| ||
n: |
|
|
|
|
|
|
| |
EWS | System | Event | Sense | Link | ||||
| ||||||||
| Event | Error | Log |
| e | Info | Incident | |
| Log | LED |
|
|
|
|
| |
|
|
|
|
|
|
|
| |
| 4 | 4 | 4 | 4 | 4 | 4 |
| |
|
|
|
|
|
|
|
|