Diagnostics
584 - Link failure -
585 - Link failure - primitive sequence timeout.
586 - Link failure - invalid primitive sequence received for the current link state. Were one or more event codes found?
YES NO
↓Perform switch fault isolation at the HAFM server. Go to step 3.
MAP 0100: Power Distribution Analysis
This MAP describes fault isolation for the switch power distribution system, including defective AC power cords or power supplies.
1
Was an event code 200, 201, 202, or 208 observed at the switch Event Log (HAFM server) or at the embedded web server event log?
YES NO
↓Go to step 3.
2
The following table lists event codes, brief explanations of the codes, and the associated steps that describe fault isolation procedures.
Event |
|
|
Code | Explanation | Action |
|
|
|
200 | Power supply AC voltage failure. | Go to step 6. |
|
|
|
201 | Power supply DC voltage failure. | Go to step 10. |
|
|
|
202 | Power supply thermal failure. | Go to step 10. |
|
|
|
208 | Power supply false shutdown. | Go to step 6. |
|
|
|
3
Is remote fault isolation being performed at the HAFM server?
YES NO