Diagnostics
7
As indicated by an event code 052, a minor internal operating error was detected by the management server subsystem. The error caused management server databases to be
Perform the data collection procedure and return the Zip disk to Hewlett Packard for analysis.
8
As indicated by an event code 062, the fabric controller software detected a path within the connected
Advise the customer of the problem and work with the system administrator to reconfigure the fabric so the path between any two fabric switches does not traverse more than seven hops.
Did fabric reconfiguration solve the problem?
NO YES
↓The switch and connected
Contact the next level of support.
9
A 070 event code indicates the E_Port detected an incompatibility with an attached switch and prevented the switches from forming a
A 071 event code indicates the switch is isolated from all switches in a
Obtain supplementary event data for the 070 event code.
a.At the switch Event Log or the embedded web server event log, record the first four bytes (0 through 3) of event data.
b.Examine the first five bytes (0 through 4) of event data.