Diagnostics
18
Both power supplies failed and must be removed and replaced (RRP: Power Supply on page
Did replacement of both power supplies solve the problem?
NO YES
↓The switch appears operational.
Contact the next level of support.
19
One or both power supplies appear operational, but the CTP card is not receiving DC power. An
Reset the switch ("Reset the Switch" on page
Did a switch reset solve the problem?
NO YES
↓The switch appears operational.
A CTP card failure is indicated. Because the CTP card is not a FRU, replace the switch
20
Does the embedded web server interface appear operational?
NO YES
↓Go to step 22.
21
A Page cannot be found, Unable to locate the server, HTTP 404 - file not found, or other similar message appears. The message indicates the web browser PC cannot communicate with the switch because:
•The
•AC power distribution in the switch failed, or AC power was disconnected.
•The switch CTP card failed.
Go to step 12.