Diagnostics

18

Both power supplies failed and must be removed and replaced (RRP: Power Supply on page 4-4). Perform the data collection procedure after FRU removal and replacement.

Did replacement of both power supplies solve the problem?

NO YES

The switch appears operational.

Contact the next level of support.

19

One or both power supplies appear operational, but the CTP card is not receiving DC power. An in-card circuit breaker may have tripped due to a power surge or the CTP card failed.

Reset the switch ("Reset the Switch" on page 3-36).

Did a switch reset solve the problem?

NO YES

The switch appears operational.

A CTP card failure is indicated. Because the CTP card is not a FRU, replace the switch

20

Does the embedded web server interface appear operational?

NO YES

Go to step 22.

21

A Page cannot be found, Unable to locate the server, HTTP 404 - file not found, or other similar message appears. The message indicates the web browser PC cannot communicate with the switch because:

The switch-to-PC Internet (Ethernet) link could not be established.

AC power distribution in the switch failed, or AC power was disconnected.

The switch CTP card failed.

Go to step 12.