Diagnostics

14

The SBAR on the CTP card failed. Because the SBAR is not a FRU, SBAR failure requires replacing the switch.

Contact the next level of support.

MAP 0600: Port Failure and Link Incident Analysis

This MAP describes fault isolation for small form factor pluggable (SFP) transceivers and Fibre Channel link incidents. Failure indicators include:

The amber LED adjacent to a Fibre Channel port illuminates.

The amber emulated LED adjacent to a port graphic at the Hardware View illuminates.

A blinking red and yellow diamond (failed FRU indicator) or yellow triangle (attention indicator) appears at the Product View or Hardware View.

An event code recorded at the switch Event Log or the embedded web server event log.

A port failure message at the Port Properties dialog box or embedded web server interface.

A link incident message at the Link Incident Log or Port Properties.

1

Was an event code 080, 440, 504, 506, 507, 508, 512, 514, or 604 observed at the switch Event Log (HAFM server) or at the embedded web server event log?

NO YES

Go to step 3.

2

Was an event code 581, 582, 583, 584, 585, or 586 observed at the console of an OSI or FICON server attached to the switch reporting the problem.?

YES NO

Go to step 4.