Diagnostics
g.Monitor port operation for approximately five minutes. Did the link incident recur?
YES NO
↓The Fibre Channel link and switch appear operational.
29
Disconnect the
Is a link incident reported at the new port?
YES NO
↓Go to step 31.
30
The attached device is causing the recurrent link incident. Notify the customer of the problem and have the system administrator:
a.Inspect and verify operation of the attached device.
b.Repair the attached device if a failure is indicated.
c.Monitor port operation for approximately five minutes.
Did the link incident recur?
YES NO
↓The attached device, Fibre Channel link, and switch appear operational.
Contact the next level of support
31
The switch port reporting the problem is causing the recurrent link incident. The recurring link incident indicates port degradation and a possible pending failure. Go to step 11.
32
An implicit incident error (event code 581), loss of signal or loss of synchronization (event code 583), not operational primitive sequence (NOS) received (event code 584), or SBAR module failure (event code 604) caused the switch to fault.
Perform the data collection procedure and return the Zip disk to Hewlett Packard for analysis.