Lucent Technologies 555-661-140 manual 400EM Tie Trunk Module DIP Switches, Simplex Mode

Models: 555-661-140

1 355
Download 355 pages 10 Kb
Page 101
Image 101

MERLIN LEGEND Communications System Release 6.1

Issue 1

Installation 555-661-140

August 1998

Installing the Control Unit

Page 2-36

Installing the Modules

 

 

E&M Mode

Type 1 Standard (default factory setting). This setting is used to connect two systems through local telephone company facilities.

Type 1 Compatible. This setting connects two systems directly (without using local telephone company facilities).

Simplex Mode

Type 5. This setting is used on 4-wire (2-pair) circuits.

400EM (Tie Trunk) Module DIP Switches

During installation of 400EM (Tie Trunk) modules, refer to Table 2–4 and Table 2–5, and to Figure 2-11 on page 2-38 for the correct DIP switch settings for varying signaling protocols.

Table 2-4. Setting the 400EM (Tie Trunk) Module DIP Switches

 

Ports

DIP

 

Signaling Type

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1S (Default)

 

 

 

 

(as numbered in

Switch

and 1C

 

1C and 1S

 

5

Figure 2-11)

Position

Unprotected

 

Protected

 

Simplex

 

 

 

 

E&M Mode

 

E&M Mode

 

Mode

 

 

 

 

 

 

 

 

 

 

 

 

1

ON

 

OFF

 

OFF or ON

 

 

 

 

 

 

 

 

 

 

 

 

2

ON

 

OFF

 

OFF or ON

 

 

 

 

 

 

 

 

 

2

 

4

3

OFF

 

OFF

 

ON

 

 

 

 

 

 

 

 

4

OFF

 

OFF

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

OFF

 

OFF

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

6

ON

 

OFF

 

OFF or ON

 

 

 

 

 

 

 

 

 

 

 

 

7

ON

 

OFF

 

OFF or ON

 

 

 

 

 

 

 

 

 

1

 

3

8

OFF

 

OFF

 

ON

 

 

 

 

 

 

 

 

9

OFF

 

OFF

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

OFF

 

OFF

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 