Lucent Technologies 555-661-140 manual Unit Load Calculation Worksheet B-9 Unit Load Worksheet

Models: 555-661-140

1 355
Download 355 pages 10 Kb
Page 338
Image 338

MERLIN LEGEND Communications System Release 6.1

Issue 1

Installation 555-661-140

August 1998

Unit Load Calculation Worksheet

Page B-9

Unit Load Worksheet

 

 

9.Try to exchange modules between carriers to reduce the unit loads for slots five and six through 27. (Remember that the 100D, 400 (LS), 400 GS/LS/TTR, 800 GS/LS-ID, 800, 800 NI-BRI, and 800 GS/LS modules have unit loads of 0.0.) Repeat Steps 1 through 8 to recalculate unit loads for new configuration.

If the exchange reduces the unit load for slots five and six through 27 or less, power is sufficient.

If the exchange does not reduce the unit loads for slots 5 and 6 through 27, install wall power units for the appropriate number of telephones to reduce the unit load to 27.

NOTE:

Empty slots are not permitted between modules.

Page 338
Image 338
Lucent Technologies 555-661-140 manual Unit Load Calculation Worksheet B-9 Unit Load Worksheet