Lucent Technologies 555-661-140 manual  Install Merlin Legend hardware

Models: 555-661-140

1 355
Download 355 pages 10 Kb
Page 298
Image 298

MERLIN LEGEND Communications System Release 6.1

Issue 1

Installation 555-661-140

August 1998

Installing Applications

Page 8-29

Installing a CTI Link

 

 

A brand-new, 4-pair cable must be installed. No reuse of wire is supported. Proper Systimax hardware must be used, including cords and connecting blocks.

Hardware Requirements

There are no new hardware requirements in Release 5.0 of the MERLIN LEGEND Communications System.

The CTI link plugs into an available port on an 008 MLX or 408 MLX module. However, the firmware vintage for the module must be other than 29. An earlier or future vintage must be used for CTI link operation. If the firmware vintage is 29, the link administration is prevented and the System Programming screens tell you that the firmware 29 cannot be used.

A summary of the installation procedure is provided below:

These steps should be followed in order. Step 2 cannot come before

Step 1, or System Programming will fail (procedure error beeps).

! Install MERLIN LEGEND hardware.

Choose a slot for an MLX port module (008 MLX or 408 MLX), and insert the module. Identify a port on that MLX port module for the CTI link. Unplug any telephone/adjunct from that port.

NOTE:

Make sure that the MLX board’s firmware vintage is NOT 29. Any other vintage is acceptable, that is, earlier or future vintages after

29.If the port module has firmware vintage 29, the link administration is prevented and the System Programming screens tell the administrator that firmware 29 cannot be used.

Do not assign the CTI link to the first and fifth ports normally reserved for the operator positions.

Page 298
Image 298
Lucent Technologies 555-661-140 manual  Install Merlin Legend hardware