MERLIN LEGEND Communications System Release 6.1

Issue 1

Installation 555-661-140

August 1998

Connecting the Control Unit to the Network Interface

Page 4-14

Testing Trunks

 

 

! If you find a central office trunk that does not have dial tone, check for a bad adapter or loose connection.

If adapters and wiring are in working order but you still do not hear a dial tone, notify the Lucent Technologies Service Center acting as the customer’s agent.

! When you hear a dial tone, dial a known telephone number to verify dialing.

After the central office completes the connection, check that you have good two-way transmission.

! If you cannot dial out on any of the trunks, notify the Lucent Technologies Service Center acting as the customer’s agent.

It is the customer’s responsibility (or that of the customer’s agent) to report service outages to the local telephone company.

Testing Ground-Start Trunks

To perform this test, you need a single-line telephone with a ground key or a ground-start button.

NOTE:

If a single-line telephone with a ground key or ground-start button is not available, ground one side of the trunk.

To test ground-start trunks, follow the steps below:

! Plug the single-line telephone into each central office line/trunk jack (either at the network interface or at the cross-connect field).

! Pick up the handset.

You should hear a dial tone.

! Ground the ring lead by pushing the ground key or ground button, or by grounding one side of the trunk.

! Remove the ground from the ring lead.

Page 189
Image 189
Lucent Technologies 555-661-140 manual Testing Ground-Start Trunks