Installation 555-661-140

August 1998

Installing Telephones and Adjuncts

Page 3-22

Installing Adjuncts

 

 

c.Plug the power supply into a 117-V AC outlet that is not controlled by a wall switch.

d.Insert the plug end of the 400B or 400B2 adapter into the wall jack.

! Test the MFM for T/R operation.

See “Testing MLX Telephones with MFMs” in Chapter 7.

! Attach the adjunct to the MFM. See “Installing Adjuncts.”

Installing Adjuncts

This section provides general instructions for connecting most adjuncts.

NOTE:

If you need to connect the adjuncts differently from the instructions on the system forms, record each jack and adjunct change on the appropriate system numbering form. See Appendix A, “System Numbering Forms.”

! Connect one end of the cord packaged with the adjunct (usually a D4BU cord) to the adjunct.

See the documentation packaged with the adjunct for instructions.

! Check the system form for the adjunct you want to connect. Then refer to the appropriate step below.

To connect an adjunct to an MLX telephone, go to Step 3.

To connect an adjunct to a single-line telephone, go to Step 4.

To connect an adjunct to an analog multiline telephone, go to Step 5.

To connect an adjunct to a 012 or 016 (T/R) module, go to Step 6.

When you connect adjuncts to telephones, make sure you route the adjunct and D8W telephone cords through the cord channel. See Figure 3–20.