MERLIN LEGEND Communications System Release 6.1

Issue 1

Installation 555-661-140

August 1998

Installing Telephones and Adjuncts

Page 3-24

Installing Adjuncts

 

 

! To connect an adjunct to an analog multiline telephone:

a.Connect a 4-pair cord to the OTHER jack on the telephone.

b.Connect the other end to the VT jack on a General Purpose Adapter (GPA).

c.Connect the cord from the adjunct to the TEL/EQUIP jack on the GPA.

d.Go to Step 7.

Refer to “General Purpose Adapter” below for additional information.

! Insert the other end of the adjunct cord directly into the port for the logical ID on the 012 or 016 (T/R) module as indicated on the system form. Go to Step 7.

! Test the adjunct by dialing its associated extension.

General Purpose Adapter

A General Purpose Adapter (GPA) lets you connect a T/R device—such as a single-line telephone or modem—to an analog multiline telephone. The device must be touch-tone, not rotary.

NOTE:

The GPA is intended for answer-only service, unless the telephone has direct access to a line. It does not have touch-tone receivers or pulse dial detectors; therefore, the associated analog multiline telephone must dial calls.

The GPA cannot be used with a MERLIN II System Display Console.

When the system forms indicate a GPA for installation of an adjunct, follow the steps below.

! Plug one end of a 4-pair adjunct D8AC cord into the VT jack on the back of the GPA.

! Plug the other end into the OTHER jack on the underside of the analog multiline telephone.

! Plug the cord from the adjunct into the TEL EQUIP jack on the GPA.

Page 135