Lucent Technologies 555-661-140 manual Testing did Trunks, Testing Tie Trunks

Models: 555-661-140

1 355
Download 355 pages 10 Kb
Page 254
Image 254

MERLIN LEGEND Communications System Release 6.1

Issue 1

Installation 555-661-140

August 1998

Initializing and Testing the System

Page 7-9

Testing the System

 

 

Testing DID Trunks

To test DID trunks, follow the steps below:

! Have someone at the central office check all DID trunks, or have someone call from the outside to check each DID trunk.

! When the first trunk rings, answer it.

! Instruct the caller to put the call on hold or put down the handset while making the next call.

! When the next trunk rings, put the previous call on hold and repeat this procedure until all eight DID trunks have been connected successfully.

! When all trunks are connected with good communication, disconnect each call and have the caller do the same.

Testing Tie Trunks

Before you test tie trunks, make sure that the tie trunks for the system are connected and properly programmed. Have someone at the far end ready to place and receive calls throughout the testing procedures listed below.

The tie trunk testing procedures in this section are as follows:

Automatic-start two-way (both incoming and outgoing)

Automatic-start incoming only

Automatic-start outgoing only

Dial-repeating two-way (both incoming and outgoing)

Dial-repeating incoming only

Dial-repeating outgoing only

Page 254
Image 254
Lucent Technologies 555-661-140 manual Testing did Trunks, Testing Tie Trunks