MERLIN LEGEND Communications System Release 6.1

Issue 1

Installation 555-661-140

August 1998

Installing the Control Unit

Page 2-10

AC Power and Grounding

 

 

 

 

 

 

 

 

110 - 125 Volts AC

Phase

Neutral (HOT)

Ground

Less than 1.0 Volt AC

110 - 125 Volts AC

Figure 2-2. Measuring the AC Outlet Voltages

! WARNING:!

If the voltage readings do not measure the values required, the AC outlet is improperly wired— do not install the system. Advise the customer to have a licensed electrician correct the problem.

Grounding Requirements

Proper grounding of the installation site safeguards the system by protecting it from the following:

Lightning

Power surges

Power crosses on central office trunks

Electrostatic discharge (ESD)

When installing the control unit, make sure you meet the following grounding requirements:

The control unit, the central office trunk protector, and the AC power service panel should be as close to each other as possible.

Page 75
Image 75