Lucent Technologies 555-661-140 Terminal Adapter and CSU Settings, Terminal Adapter Settings

Models: 555-661-140

1 355
Download 355 pages 10 Kb
Page 244
Image 244

MERLIN LEGEND Communications System Release 6.1

Issue 1

Installation 555-661-140

August 1998

Connecting Data Equipment

Page 6-21

Video Conferencing Data Stations

 

 

c.Use the DB-37 cables to connect the EIA-232/V.35 converters to the video codec’s V.35 communication ports. See the documentation packaged with the video codec for instructions.

! If it is not already connected, connect the CSU to the 100D module on the control unit and to the 5ESS or 4ESS exchange switch.

See “Installing the Channel Service Unit” in Chapter 4.

! When you are ready to power up the system, plug the power supplies, CSU, video conferencing equipment, and control unit into the AC outlets.

Terminal Adapter and CSU Settings

You need to set the terminal adapter and the CSU as indicated in Table 6–2. If the customer’s system is running at 56 kbps, set the CSU line-coding DIP switches according to the instructions in “Setting the CSU DIP Switches” in Chapter 4.

Table 6-2. Terminal Adapter Settings

Settings

56 Kbps

64 Kbps

Auto-dial

Off

Off

 

 

 

Busy out

Off

Off

 

 

 

Datarest

On

Off

 

 

 

DTR

Follow

Follow

 

 

 

Duplex

Full

Full

 

 

 

Mode

Cs

Cs

 

 

 

Speed

56,000

64,000

 

 

 

Page 244
Image 244
Lucent Technologies 555-661-140 manual Terminal Adapter and CSU Settings, Terminal Adapter Settings