MERLIN LEGEND Communications System Release 6.1

Issue 1

Installation 555-661-140

August 1998

Installing the PC, CAT, or Printer

Page 5-21

Connecting a Printer to the Control Unit

 

 

If the 400B2 is plugged into a wall jack, make sure that building wiring has been set up so that the wall jack for the control unit can communicate with the wall jack for the printer.

If the 400B2 is plugged into a BR1A-4P adapter, 102 connecting block, or 103 connecting block, use 4-pair plug-ended cable to connect the BR1A-4P adapter (or connecting block) to the wall jack for the printer.

! On the printer side, plug one end of a D8W cord into the wall jack and the other end into the WALL jack on the Z3A2 ADU.

! Plug one end of an EIA-232-D cable into the 25-pin male connector on the Z3A2 ADU and the other end into the serial port on the printer.

! Plug the 2012D-50M (or 2012D) transformer into a wall outlet.

! Set the appropriate printer options for SMDR.

See “Setting Printer Options and DIP Switches” for instructions.

Setting Printer Options and DIP Switches

If the customer has an Lucent Technologies 572, Lucent Technologies 475/476, CAT, or Lucent Technologies Applications printer, use this section to set up printer options. If another type of serial printer is being used, review these setup options for guidance and consult the manual for the printer. Use the information below to determine the correct printer setting for the printer:

For the 572 printer, set the options on the printer according to Table 5–1.

(See the user’s guide supplied with the printer for more information.)

For the 475/476 printer, set the DIP switches on the printer according to Table 5-2 on page 5-24. (See the user’s guide supplied with the printer for more information.)

Page 218
Image 218
Lucent Technologies 555-661-140 manual Setting Printer Options and DIP Switches