Issue 1

Installation 555-661-140

August 1998

Installing the PC, CAT, or Printer

Page 5-11

Connecting a Printer to the Control Unit

 

 

NOTE:

If you are installing the printer in a different room than the control unit, make sure that both locations have working wall outlets and wall jacks, and that the building wiring has been connected so that the wall jacks in each location connect with each other.

You need the following hardware for the following procedure:

248B adapters

355AF, 355A adapters

400B2 power adapters

D8W cords

D6AP power cords

D8AM modular crossover cable

M7U null modem cable (25-pin cable)

Z3A2, Z3A4 ADUs

2012D transformer

Z200A EMI filter

To connect a CAT printer on a different AC outlet, first make the connections at the control unit, then at the printer.

Follow the steps below to make the connections at the control unit.

Refer to Figure 5–4 throughout the procedure.

! Plug the short end of a Z200A EMI cord into the SMDR jack on the control unit.

! Plug the other end of the Z200A EMI cord into a 355AF adapter.

! Plug the 355AF into one end of an M7U null modem cable.

! Plug the other end of the M7U null modem cable into the 25-pin female connector on a Z3A4 ADU.