MERLIN LEGEND Communications System Release 6.1

Issue 1

Installation 555-661-140

August 1998

Installing the Control Unit

Page 2-33

Installing the Modules

 

 

Installing the Modules

! CAUTION:

When installing the modules, use a properly grounded wrist strap to prevent damage from electrostatic discharge (ESD), and avoid touching leads, connectors pins, and other components.

Guidelines

Follow these guidelines when you install modules, as indicated on the

Control Unit Diagram of Form 1, System Planning:

Do not leave empty slots between modules. The system ignores modules installed beyond any empty slot.

If a phantom module (a programmed empty slot) is indicated on the Control Unit Diagram, make sure the slot remains empty and do not install any modules to the right of it. The system ignores any modules installed to the right of a programmed empty slot.

Make sure you install each module in its assigned slot. If you install a module in the wrong slot, the system will not function properly.

Be sure to place all 012 modules and all 008 OPT modules without built-in ring generators in carriers with modules that have ring generators so that the modules without ring generators can be supported.

NOTE:

All 016 (T/R) modules and some 012 modules (apparatus code 517G13 or later) have built-in ring generators.

Once you have installed the power supply and the processor in the basic carrier, use the remaining slots for the modules as follows:

Basic carrier: slots 1 through 5

First expansion carrier: slots 6 through 11

Second expansion carrier: slots 12 through 17