Lucent Technologies 555-661-140 manual Testing Outgoing Dial-Repeating Tie Trunks

Models: 555-661-140

1 355
Download 355 pages 10 Kb
Page 257
Image 257

MERLIN LEGEND Communications System Release 6.1

Issue 1

Installation 555-661-140

August 1998

Initializing and Testing the System

Page 7-12

Testing the System

 

 

! Have the person at the far end place a dial-repeating call to your telephone by dialing the proper tie-trunk number.

Your telephone rings and the green LED next to ICOM (or SA for Hybrid/PBX systems) flashes.

! Pick up the handset.

The red LED next to the ringing button turns on and the green LED changes from flashing to steady.

! Verify that you have good two-way communication and hang up. The green LED should turn off, the red LED should turn off, and another red LED may turn on.

! Repeat Steps 1 through 3 for each incoming or two-way

dial-repeating tie trunk.

Testing Outgoing Dial-Repeating Tie Trunks

Perform this test for dial-repeating tie trunks that are two-way or outgoing only. If you are testing dial-repeating two-way tie trunks, perform the incoming test as well.

To test outgoing dial-repeating tie trunks, follow the steps below:

! At any telephone that has access to a dial-repeating tie trunk, press the first tie-trunk button.

The red LED next to the pressed tie-trunk button lights.

! Pick up the handset. (In Hybrid/PBX systems with pooled tie trunks, press an SA button and dial the pool dial-out code.)

The green LED next to the selected button lights.

! Dial the tie-trunk number of the extension where someone is waiting for your call.

You should hear ringing.

Page 257
Image 257
Lucent Technologies 555-661-140 manual Testing Outgoing Dial-Repeating Tie Trunks, You should hear ringing