MERLIN LEGEND Communications System Release 6.1

Issue 1

Installation 555-661-140

August 1998

Installing the PC, CAT, or Printer

Page 5-5

Connecting a PC to the Control Unit

 

 

! CAUTION:

If the PC is in a building outside the main building (control unit location), you must install an ADU and an additional protector in each building. The ADUs and protectors provide both the control unit and the PC with additional protection against lightning, inadvertent contact with power lines, and power currents induced by nearby power lines. For more information, see the installation notes packaged with the ADU.

! Plug one end of a D8W cord into the WALL jack on the Z3A2 ADU and connect the other end to an ADU crossover cable.

! Plug the other end of the ADU crossover cable into one of the jacks on a 400B2 power adapter.

! Plug one end of a D6AP cord into the 400B2 power adapter.

! Plug the other end of the D6AP cord into a 2012D-50M transformer.

! Plug the 400B2 power adapter into a wall jack, BR1A-4P adapter, 102 connecting block, or 103 connecting block.

If you plug the 400B2 into a wall jack, make sure the building wiring has been set up so that the wall jack near the control unit is connected to the wall jack near the PC.

If you plug the 400B2 into a BR1A-4P adapter, 102 connecting block, or 103 connecting block, use 4-pair plug-ended cable to connect the BR1A-4P adapter (or connecting block) to the wall jack near the PC.

Page 202
Image 202
Lucent Technologies 555-661-140 manual Merlin Legend Communications System Release