MERLIN LEGEND Communications System Release 6.1

Issue 1

Installation 555-661-140

August 1998

Installing the Control Unit

Page 2-41

Replacing a Module

 

 

Replacing a Module

! CAUTION:

This section does not apply to the processor or power supply.

Although the system allows you to remove and replace modules without affecting call processing, partially inserting and removing a module can cause a cold start.

To add a 100D module or change any of its DS1 parameters, the system must be idle.

When you replace a module, use the same module type. For example, do not put an 008 MLX module in place of a 400 GS/LS/TTR module. If a module is replaced with another type of module, or if a module is added to the system without powering down the system first, a cold start (System Reset) occurs.

If you move any module to a different slot, be sure to renumber the modules by selecting %PBSE￿5FOVNCFS from system programming. See System Programming for information about board renumbering.

NOTE:

You can remove and replace line/trunk and extension modules with the system power on, without affecting normal call processing.

Page 106
Image 106
Lucent Technologies 555-661-140 manual Replacing a Module