Initializing and Testing the System

Page 7-15

Testing the System

 

 

! At the ringing telephone, have someone pick up the handset and verify that you have good two-way communication.

! Repeat Steps 2 and 3 for each calling group.

! Make additional calls to check each member of each calling group.

! At any telephone, pick up the handset and dial the group extension number.

! Test the calling group delay announcement (if provided) for each group.

a.Make the group busy or have all members log out of the group (by dialing ￿￿￿￿￿at each group extension).

b.Repeat Step 2.

c.After listening to the delay announcement, hang up.

d.Repeat these steps for each group.

! At the ringing telephone, have someone pick up the handset and verify that you have good two-way communication.

System Speed Dial Test

To test System Speed Dial numbers, follow the steps below:

! Find out which numbers have been programmed for System Speed Dial.

See the system manager or use Form 10b as a reference for System Speed Dial numbers.

! From the test telephone, pick up the handset and dial a System Speed Dial code.

Verify that you have good two-way communication and that the correct party was reached.