MERLIN LEGEND Communications System Release 6.1

Issue 1

Installation 555-661-140

August 1998

Connecting the Control Unit to the Network Interface

Page 4-8

Wiring

 

 

 

 

 

 

 

 

AT-8762 D

Impact Tool

110 Impact Tool

788J1

788 K1 Retainer Tool

Spudger

Modular Plug Pressers

Figure 4-3. RJ21X Wiring Field Tools

To connect the RJ21X network interface to the control unit, follow the steps below. Figure 4–3 shows the tools you need.

! For each piece of hardware, drill two diagonally opposite holes into the backboard, allowing for a 1/16-inch (1.6 mm) space between each piece of hardware.

! Mount the wire troughs and the termination blocks.

There is a wire trough above and below each termination block.

Page 183
Image 183
Lucent Technologies 555-661-140 manual RJ21X Wiring Field Tools