Lucent Technologies 555-661-140 manual Merlin Legend Communications System Release

Models: 555-661-140

1 355
Download 355 pages 10 Kb
Page 215
Image 215

MERLIN LEGEND Communications System Release 6.1

Issue 1

Installation 555-661-140

August 1998

Installing the PC, CAT, or Printer

Page 5-18

Connecting a Printer to the Control Unit

 

 

2012D transformer

248B adapter

D8W cords

D6AP power cord

EIA-232-D cable

4-pair plug-ended cable

To connect a printer 50 ft. (15.2 m) or further away from the control unit, follow the steps below. See Figure 5–6.

! Plug the short end of a Z200A EMI cord into the SMDR jack on the control unit.

! Plug the other end of the Z200A EMI cord into a 355AF adapter.

! Plug the female end of the 355AF adapter into one end of an EIA crossover cable.

! Plug the other end of the EIA cable into the 25-pin male connector of the Z3A2 ADU.

! CAUTION:

If the printer is in a building outside the main building (control unit location), you must install an ADU and an additional protector in each building. The ADUs and protectors provide both the control unit and the printer with additional protection against lightning, inadvertent contact with power lines, and power currents induced by nearby power lines. See the installation notes packaged with the ADU for more information.

! Plug one end of a D8W cord into the WALL jack on the Z3A2 ADU.

! Plug the other end of the D8W cord into an ADU crossover cable.

! Plug the other end of the ADU crossover cable into one of the jacks on a 400B2 power adapter.

! Plug one end of a D6AP cord into the other jack of the 400B2 adapter.