NEC 1080Xd 35. HC Subcommands cont’d, Service Processor, arg1, arg2, arg3, arg4, Description

Models: 1080Xd

1 216
Download 216 pages 14.64 Kb
Page 93
Image 93
Manual background

Table 3-35. HC Subcommands (cont’d)

cmd

arg1

arg2

arg3

arg4

Description

ncconn

-

-

-

-

Used to set connection information of the 1.6G

 

 

 

 

 

cable.

 

 

 

 

 

Displays Help for “ncconn” when the argument

 

 

 

 

 

is omitted or an error is made.

 

 

 

 

 

This subcommand can be executed when all

 

 

 

 

 

partitions are in the DC POWER OFF state.

 

 

 

 

 

 

 

xbcx

nciy

iors

ncit

Specifies the connection between the 1.6G port

 

 

 

 

 

with the port number y in the XBC chip with the

 

iors

ncit

xbcx

nciy

physical number x and the 1.6G port with the

 

 

 

 

 

port number t in the IOR chip with the physical

 

 

 

 

 

number s.

 

 

 

 

 

t must be (0).

 

 

 

 

 

 

ncdis

-

-

-

-

Used to disconnect the 1.6G cable.

 

 

 

 

 

Displays Help for “ncdis” when the argument is

 

 

 

 

 

omitted or an error is made.

 

 

 

 

 

This subcommand can be executed when all

 

 

 

 

 

partitions are in the DC POWER OFF state.

 

 

 

 

 

 

 

xbcx

nciy

-

-

Removes the connection of the 1.6G port with

 

 

 

 

 

the port number y in the XBC chip with the

 

 

 

 

 

physical number x.

 

 

 

 

 

It is linked to the disconnection of the

 

 

 

 

 

corresponding port (and vice versa).

 

 

 

 

 

 

 

iors

ncit

-

-

Removes the connection of the 1.6G port with

 

 

 

 

 

the port number t in the IOR chip with the

 

 

 

 

 

physical number s. t must be (0).

 

 

 

 

 

It is linked to the disconnection of the

 

 

 

 

 

corresponding port (and vice versa).

 

 

 

 

 

 

led

-

-

-

-

Used to turn on/off a component’s LED to

 

 

 

 

 

identify its location.

 

 

 

 

 

Displays Help for “led” when the argument is

 

 

 

 

 

omitted or an error is made.

 

 

 

 

 

For execution on XBC (XIC Board/XBR Board)

 

 

 

 

 

and CELLV Board, one of the partitions must be

 

 

 

 

 

in the DC POWER ON state.

 

 

 

 

 

For execution on the PCIX, no condition is

 

 

 

 

 

required.

 

 

 

 

 

For execution on the PCI slot, the superior GXB

 

 

 

 

 

must be in the online state.

 

 

 

 

 

 

 

xbcx

onoff

-

-

Turns on/off the LED of the XIC Board/XBR

 

 

 

 

 

Board.

 

 

 

 

 

x” is specified as below.

 

 

 

 

 

0: XIC Board

 

 

 

 

 

1: XBR Board

 

 

 

 

 

 

Service Processor 3-43

Page 93
Image 93
NEC 1080Xd manual 35. HC Subcommands cont’d, Service Processor, arg1, arg2, arg3, arg4, Description