3-40 Service Processor

Table 3-35. HC Subcommands (cont’d)

cmd

arg1

arg2

arg3

arg4

Description

enable

 

serialx

-

-

Enables the serial controller part within the XBC

(cont’d)

 

 

 

 

chip.

 

 

 

 

 

x” is the serial controller number (0-3).

 

 

 

 

 

A partition requires a serial controller. When a

 

 

 

 

 

partition contains plural CELLV Boards, a serial

 

 

 

 

 

controller is selected from available serial

 

 

 

 

 

controllers automatically.

 

 

 

 

 

 

 

cellx

[all]

-

-

Enables the CELLV Board.

 

 

 

 

 

x” is the physical CELLV Board number (0-3).

 

 

 

 

 

When the second argument is omitted, only the

 

 

 

 

 

CELLV Board is enabled, and the states of any

 

 

 

 

 

other subcomponents do not change. In this

 

 

 

 

 

case, operation is rejected if some required

 

 

 

 

 

components are disabled.

 

 

 

 

 

When “all” is specified as the second argument,

 

 

 

 

 

not only the CELLV Board but also its

 

 

 

 

 

subcomponents become enabled.

 

 

 

 

 

 

 

 

cxiy

-

-

Enables the XBC interface part within the

 

 

 

 

 

CELLV Board.

 

 

 

 

 

y” is the interface part number (0-1).

 

 

 

 

 

For information on the relationship between the

 

 

 

 

 

CXI within the CELLV Board and the CXI within

 

 

 

 

 

the XBC chip, refer to “cxix” of “xbcx” in

 

 

 

 

 

“enable”.

 

 

 

 

 

 

 

procxy

-

-

-

Enables the Processor.

 

 

 

 

 

x” is the physical CELLV Board number (0-3).

 

 

 

 

 

y” is the Processor number (0-3) within the

 

 

 

 

 

CELLV Board .

 

 

 

 

 

 

 

mmcxy

[all]

-

-

Enables the MMC.

 

 

 

 

 

x” is the physical CELLV Board number (0-3).

 

 

 

 

 

y” is the MMC number (0-1) within the CELLV

 

 

 

 

 

Board.

 

 

 

 

 

When the second argument is omitted, only the

 

 

 

 

 

MMC is enabled, and the states of any other

 

 

 

 

 

subcomponents do not change.

 

 

 

 

 

When “all” is specified as the second argument,

 

 

 

 

 

not only the MMC but also its subcomponents

 

 

 

 

 

become enabled.

 

 

 

 

 

 

 

 

rowz

-

-

Enables the ROW.

 

 

 

 

 

z” is the ROW number (0-3).

 

 

 

 

 

DIMM is not controlled individually.

 

 

 

 

 

DIMMs are automatically detected at the time of

 

 

 

 

 

startup.

 

 

 

 

 

 

3-40 Service Processor