Table 3-35. HC Subcommands (cont’d)

cmd

arg1

arg2

arg3

arg4

Description

loc

pbayxy

d

h

-

Specifies the location and height of the Power

(cont’d)

 

 

 

 

Bay Unit in the cabinet.

 

 

 

 

 

x” is the unit ID number.

 

 

 

 

 

1: Power Bay Unit

 

 

 

 

 

0: Not allowed

 

 

 

 

 

y” is the ID number. (0) must be specified.

 

 

 

 

 

d” is the position of the lower edge of the unit in

 

 

 

 

 

decimal (0-63) by using the EIA unit.

 

 

 

 

 

(1 EIA unit = 44.45mm)

 

 

 

 

 

h” is the height of the unit (3).

 

 

 

 

 

 

 

pcixx

c

d

 

Specifies the location and height of the PCIX

 

 

 

 

 

Unit in the cabinet.

 

 

 

 

 

x” is the PCIX Unit number (1-3).

 

 

 

 

 

c” must be (1).

 

 

 

 

 

d” is the position of the lower edge of the unit in

 

 

 

 

 

decimal (0-63) by using the EIA unit.

 

 

 

 

 

(1 EIA unit = 44.45mm).

 

 

 

 

 

 

check

-

-

-

-

Checks the current configuration information

 

 

 

 

 

from the following points:

 

 

 

 

 

Presence of units whose location information

 

 

 

 

 

is not entered

 

 

 

 

 

Presence of “DISABLE” components

 

 

 

 

 

Presence of “INVISIBLE” units

 

 

 

 

 

Configuration violating the installation

 

 

 

 

 

restrictions

 

 

 

 

 

Configuration with penalty in

 

 

 

 

 

performance/RAS.

 

 

 

 

 

This subcommand can be executed in the AC

 

 

 

 

 

POWER ON state or DC POWER ON state.

 

 

 

 

 

 

Service Processor 3-45

Page 95