NEC 1080Xd 35. HC Subcommands cont’d, Service Processor, arg1, arg2, arg3, arg4, Description

Models: 1080Xd

1 216
Download 216 pages 14.64 Kb
Page 85
Image 85
Manual background

Table 3-35. HC Subcommands (cont’d)

cmd

arg1

arg2

arg3

arg4

Description

attach

iorx

n

m

p

Associates the IOR having the physical number

(cont’d)

 

 

 

 

x with the logical IOR number m of partition n.

 

 

 

 

 

(m: The number recognizable by the BIOS and

 

 

 

 

 

software.)

 

 

 

 

 

p(0-9) sets the priority.

 

 

 

 

 

Indicates which IOR is used with a higher

 

 

 

 

 

priority if the number of normal CELLV Boards is

 

 

 

 

 

smaller than the number of normal IORs due to

 

 

 

 

 

CELLV Board failure in the partition. (Smaller

 

 

 

 

 

values have a higher priority, and the IORs with

 

 

 

 

 

larger values get isolated one by one. If the

 

 

 

 

 

priority number is the same, the one with a

 

 

 

 

 

smaller physical IOR number has a higher

 

 

 

 

 

priority.)

 

 

 

 

 

This command can be used to change the

 

 

 

 

 

logical IOR number and priority if it has been

 

 

 

 

 

already associated.

 

 

 

 

 

The logical IOR number must be unique within

 

 

 

 

 

the partition.

 

 

 

 

 

You cannot change the logical IOR number or

 

 

 

 

 

priority of the IOR which is in the online state.

 

 

 

 

 

"Priority 0" is allowed one time for one partition

 

 

 

 

 

and a Basic I/O Board must be connected. If

 

 

 

 

 

any failure occurs in this IOR, the partition

 

 

 

 

 

cannot be started.

 

 

 

 

 

The IOR0 must have priority 0.

 

 

 

 

 

 

detach

-

-

-

-

Used to cancel the associations between

 

 

 

 

 

partition numbers and CELLV Boards/IORs.

 

 

 

 

 

You cannot detach any component that is in the

 

 

 

 

 

online state.

 

 

 

 

 

The number of CELLV Boards in a partition

 

 

 

 

 

must be greater than or equal to the number of

 

 

 

 

 

IORs.

 

 

 

 

 

Displays Help of “detach” when the argument is

 

 

 

 

 

omitted or an error is made.

 

 

 

 

 

 

 

cellx

-

-

-

Disassociates the CELLV Board having the

 

 

 

 

 

physical number x from the currently associated

 

 

 

 

 

partition.

 

 

 

 

 

 

 

iorx

-

-

-

Disassociates the IOR having the physical

 

 

 

 

 

number x from the currently associated partition.

 

 

 

 

 

 

Service Processor 3-35

Page 85
Image 85
NEC 1080Xd manual 35. HC Subcommands cont’d, Service Processor, arg1, arg2, arg3, arg4, Description