Installation

Power connection

Installation

L N

01 02 03

01BROWN or BLACK

02BLUE or WHITE

03YELLOW and GREEN

Plug the oven into an electrical socket. If a plug-type socket is not available due to allowable current limitations, use a multi- pole isolator switch (with at least 3 mm spacing in-between) in order to meet safety regulations. Use a power cord of sufficient length that supports the specification H05 RR-F or H05 VV-F, min. 1.5~2.5 mm².

Rated current(A)

Minimum cross-

 

sectional area

 

 

10 < A ≤ 16

1.5 mm2

 

 

16 < A ≤ 25

2.5 mm2

 

 

Check the output specifications on the label attached to the oven.

Open the rear cover of the oven using a screwdriver, and remove the screws on the cord clamp. Then, connect the power lines to the relevant connection terminals.

The ()-terminal is designed for earthgrounding. First connect the yellow and green lines (earthgrounding), which must be longer than the others. If you use a plug-type socket, the plug must remain accessible after the oven is installed. Samsung is not responsible for accidents caused by missing or faulty earthgrounding.

WARNING

Do not step on or twist the wires during installation, and keep them away from heat- emitting parts of the oven.

12  English

NV73J9770RS_EE_DG68-00613D-05_SV+NO+FI+DA+EN.indb 12

2018-04-06 ￿￿ 5:51:23

Page 380
Image 380
Samsung NV73J9770RS/EE manual Power connection