Toshiba dk14 Program 20 Overview, 3-55, 6SNU+ROG6SNU+ROG6SNU+ROG6SNU+ROG, System & Station, Notes

Models: dk14

1 418
Download 418 pages 533 b
Page 101
Image 101
Initialized Default: LED 17 ON, all others OFF

System & Station

Program 20 – Computer and Data Interface Unit Configuration

Program 20 – Computer and Data Interface Unit Configuration

Processor Type: DK14, DK40i, All RCTUs

Program Type: Station

Initialized Default: LED 17 ON, all others OFF

￿￿￿Program 20 Overview3-55￿￿￿Manual backgroundManual background￿￿￿￿Manual backgroundManual background￿￿￿￿Manual backgroundManual background6SNU￿￿+ROG￿Manual background6SNUManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background￿Manual backgroundManual backgroundManual backgroundManual background+ROG￿6SNU￿Manual background￿+ROG￿6SNU￿Manual background￿+ROG

SELECT = PDKU/PDSU Station Logical Port Manual background Number that is connected to PDIIU-DS or to DKT with PDIU-DI or RPCI-DI

LED Buttons 01~06 define data port type; LED Buttons 17~20 assign data port to security group.

Processor Type

Port Range

DK14

000~009

 

 

DK40i

000~027

 

 

RCTUA

000~031

 

 

Processor Type

Port Range

RCTUBA/BB

000~079

 

 

RCTUC/D

000~239

 

 

RCTUE/F

000~335

 

 

DK40i Base, PDKU, RDSU, KCDU Digital Port Number

LED

X

LED ON

LED OFF

 

 

20

 

Data Security Group 4

Not Included

 

 

 

 

 

 

 

 

19

 

Data Security Group 2

Not Included

 

 

 

 

 

 

 

 

 

 

18

 

Data Security Group 3

Not Included

 

 

 

 

 

 

 

 

17

 

Data Security Group 1

Not Included

 

System&

10

Not Used

RPCI-DI Caller ID/ANI Sent

RPCI-DI Caller ID/ANI Not Sent

 

12~16

 

 

 

 

11

 

RPCI-DI DNIS Sent

RPCI-DI DNIS Not Sent

 

 

 

 

 

 

 

Station

07~09

Not Used

 

 

 

 

 

 

 

 

 

 

 

 

 

06

 

DTR Pulse with Data Release

No DTR Pulse

 

 

05

 

Auto Pause Behind PBX

No Auto Pause

 

 

 

 

 

 

 

 

04

 

PDIU-DS Connected

PDIU-DI/RPCI-DI Connected

 

 

 

 

 

 

 

 

03

 

PDIU-DS to Modem Connection

PDIU-DS to other type DCE or DTE

 

 

 

 

 

 

 

 

 

 

02

 

AT Commands and Result Codes

AT Commands Only

 

 

 

 

 

 

 

 

01

 

PDIU-DS or RPCI Connected

No PDIU-DS or RPCI Connected

 

 

Program 20 Overview

Program 20 identifies the digital station ports connected to RPCI/PDIU and the type of PDIU connected.

RPCIs have two modes: the Data Switching (DIU mode) and the Application Program Interface (or TAPI) mode. In the DIU mode, the RPCI operates as a PDIU-DI (Integrated Data Interface Unit); all Program 20 options apply except LED 10 and LED 11 - which only apply to the RPCI in TAPI mode. In TAPI mode the RPCI does not require Program 20 assignments, except for LED 10 and/or LED 11 if ANI, DNIS, and/or Caller ID must be sent from the RPCI-DI to the PC to which it is connected.

Notes

RPCIs and PDIUs cannot be connected to PDKU1 circuit 8, but can be connected to all eight PDKU2 circuits. RPCIs and PDIUs that support data switching cannot be connected to PDKU in all slots. See DK424 Chapter 4 – DK424 Configuration, Tables 4-4 and 4-5. DK40i slots 17 and 18 do not support data switching.

Strata DK Programming 5/99

3-55

Page 101
Image 101
Toshiba dk14 Program 20 Overview, 3-55, 6SNU+ROG6SNU+ROG6SNU+ROG6SNU+ROG, System & Station, Program Type: Station, Notes